Maryville’s roughly $52 million water treatment plant (costing approximately $52.1 million to $52.5 million) is notable as the largest infrastructure project in the city’s history and as the first facility in Missouri designed to combine ozone and biological activated filtration. [1, 2, 3, 4]
Humorous Overview
- Why did the old Maryville water plant keep needing membrane replacements? Because it had commitment issues… it just couldn’t filter out a long-term relationship.
- What’s the difference between the new O3-BAF plant and a California spa day? One uses ozone and happy microbes to make the water better. The other just charges you $52 million and calls it “self-care.”
- Maryville residents after the second 50% rate increase: “I asked for a glass of water… not a second mortgage.”
- Why is the new plant so confident? Because it’s the first in Missouri to use ozone + biofiltration. Everyone else is still stuck in the “just add more chlorine and hope” era.
- Algae walking into the new treatment plant: “I used to run this lake…” Ozone and the microbes: “Not anymore, champ.”
- Local slogan suggestion: “Maryville Water — Now with the same technology as Lake Mead… and roughly the same impact on your wallet.”
Key Points
- Record Scale & Cost: Backed by a $50 million Drinking Water State Revolving Fund loan and a $2.5 million grant, it is the largest infrastructure initiative Maryville has undertaken. [1, 2]
- First-of-Its-Kind Missouri Treatment: Designed for roughly 4 million gallons per day (MGD), it will be the first plant in Missouri to use ozone and biological activated filtration to tackle taste and odor issues from Mozingo Lake algal blooms and seasonal water quality shifts. [1, 2, 3]
- Broader System & Fire Safety Upgrades: Beyond modernizing treatment, the project supports long-term regional water demand (including Nodaway Public Water Supply District #1) and replaces narrow two-inch water lines with four-inch lines to better withstand modern fire truck pumping forces. [1, 2]
- Major Rate Impacts: To meet loan revenue requirements ahead of completion projected between mid- and late 2028, water rates are scheduled for steep increases in FY 2027 and FY 2028. [1, 2, 3]
More project details and a bill calculator are available on the MaryvilleWater.org project site, while rate ordinance coverage appears in the Northwest Missouri News water report and technical background is outlined on the HDR water improvements page. [1, 2, 3, 4]
First in Missouri of Filter System
Combined Ozone and Biological Activated Filtration (O3-BAF) pairs powerful oxidation with beneficial microbes to break down complex organic matter, outperforming conventional plants in taste, odor, and chemical byproduct control.
Comparison of Municipal Water Treatment Technologies
| Feature / Metric | Combined Ozone & BAF (O3-BAF) | Conventional Filtration (Coagulation, Flocculation, Sand/Anthracite) | Granular Activated Carbon (GAC) Adsorption | Membrane Filtration (UF / NF / RO) |
|---|---|---|---|---|
| Core Mechanism | Ozone breaks down large organic molecules; microbes on filter media digest the smaller fragments. | Chemical coagulants clump particles together, which settle out and pass through sand/anthracite beds. | Porous carbon media physically traps organic molecules and chemicals via adsorption. | Pressurized water is forced through microscopic semi-permeable membranes to block contaminants. |
| Taste & Odor Control (Algal Blooms) | Superior — Destroys stubborn algal compounds (like geosmin and MIB) rather than just trapping them. | Poor to Fair — Removes suspended algae, but dissolved taste/odor compounds pass through easily. | Good — Effectively adsorbs taste/odor compounds until the carbon pores become saturated. | Fair to Excellent — Ultrafiltration (UF) misses dissolved odors; Nanofiltration (NF) and Reverse Osmosis (RO) remove them. |
| Disinfection Byproduct (DBP) Reduction | High — Consumes organic precursors biologically before final chlorine is added, sharply cutting THMs and HAAs. | Low to Moderate — Removes some organic matter, but requires higher chlorine doses that form more DBPs. | Moderate to High — High removal initially, though performance drops steadily as carbon saturates. | Moderate to High — UF provides low organic removal; NF and RO remove almost all DBP precursors. |
| Trace Organics & PFAS | Moderate to High — Breaks down pharmaceuticals and pesticides; pairs well with downstream polishing for PFAS. | Very Low — Not designed to remove dissolved synthetic chemicals or pharmaceuticals. | High — Industry standard for adsorbing PFAS, pesticides, and industrial solvents. | High (NF/RO only) — RO and NF reject PFAS and trace organics; UF does not. |
| Media Life & Operating Costs | Long Media Life — Microbes continuously self-clean the filter media, delaying costly replacements for years. | Low Operating Cost — Minimal energy demand and inexpensive sand/gravel media, but high chemical sludge volume. | High Regeneration Cost — Carbon saturates quickly and must be frequently replaced or thermally reactivated. | High Energy & Replacement Cost — High pumping energy (especially RO) and periodic membrane replacement. |
| Best Source Water Fit | Surface water lakes and reservoirs prone to seasonal algae, organics, and agricultural runoff (e.g., Mozingo Lake). | Clean, stable rivers or lakes with low dissolved organics and predictable seasonal quality. | Water supplies facing industrial chemical spills, PFAS contamination, or persistent synthetic organics. | Brackish groundwater, seawater, or surface water requiring strict pathogen and dissolved-solid removal. |
Key Takeaways for Maryville’s Approach
- Why O3-BAF Beats Standard GAC for Lakes: Standard carbon filters act like a sponge that eventually fills up, requiring expensive media change-outs every few months to a couple of years. Adding ozone turns the filter into a living biological reactor where microbes eat the broken-down organic matter, extending media life dramatically.
- Chlorine Efficiency: Because ozone provides primary disinfection and microbes eat the organic matter that normally reacts with chlorine, the plant needs far less chlorine at the end of the process, improving tap water taste and safety.
Maryville’s planned 4 MGD facility applies the same core ozone and biological activated filtration (O3-BAF) technology used by major metropolitan systems, operating at a smaller municipal scale tailored for surface-water lake treatment. [1, 2, 3, 4]
Comparison of U.S. Ozone & Biofiltration Plants (MGD is Million Gallons/Day)
| Facility & Location | Capacity | Source Water | Primary Treatment Role | Key Operational Highlights |
|---|---|---|---|---|
| Maryville Water Treatment Plant (Maryville, MO — Est. 2028) | 4 MGD | Mozingo Lake (surface reservoir) | Municipal drinking water | First O3-BAF plant in Missouri; targets seasonal algal blooms, taste/odor, and disinfection byproducts. |
| Alfred Merritt Smith Plant (Boulder City, NV) | 600 MGD | Lake Mead (surface reservoir) | Municipal drinking water | One of the world’s largest O3-BAF plants; combats Cryptosporidium, cyanotoxins, and trihalomethanes. |
| Shoal Creek & Lanier Plants (Gwinnett County, GA) | >200 MGD (combined) | Lake Lanier & Chestatee River | Municipal drinking water | Uses ozone + dual-media biofiltration (anthracite/sand); paired with a 60 MGD O3-BAC potable reuse plant. |
| North City Pure Water Facility (San Diego, CA) | 30 MGD (Phase 1 purified) | Recycled municipal wastewater | Indirect potable reuse | Uses O3-BAC as an initial organic/pharmaceutical barrier before membrane filtration, reverse osmosis, and UV. |
Key Takeaways Across Scales
- Identical Core Chemistry: Whether treating 4 MGD in northwest Missouri or 600 MGD in southern Nevada, ozone breaks down dissolved organic carbon so beneficial microbes in the filter bed can digest it before final chlorination. [1, 2, 3]
- Application Differences: Surface-water drinking plants (Maryville, Southern Nevada, Gwinnett County) rely on O3-BAF as their primary advanced barrier against algal compounds and disinfection byproducts, whereas potable reuse plants (San Diego) use O3-BAC as a pre-treatment step ahead of reverse osmosis. [1, 2, 3]